Power dissipation, mounting position, cooling, distances
Cooling and power dissipation data
Description Symbol Unit
KMV03.1R-
A05K0-P-D7-
ET-NNNN
KMV03.1R-
B0007-P-D7-
ET-NNNN
KMV03.1R-
I01K5-P-D7-
ET-NNNN
KMV03.1R-
W06K0-P-D7-
ET-NNNN
Ambient temperature range for
operation with nominal data
T
a_work
°C 0…40
Allowed mounting position G1 G1, G2, G3, G4 G1
Cooling type Air cooling Thermal interface
Forced air
cooling
Power dissipation at continuous
current and continuous DC bus
power respectively
1)
P
Diss_cont
W 390.00 500.00 220.00 430.00
Power consumption control
voltage input at U
N3
2)
P
N3
W 18
Temperature increase with
minimum distances d
bot
; d
top
; P
BD
ΔT K -
Latest amendment: 2019-08-08
1) Plus dissipation of braking resistor and control section
2) See information on "Rated power consumption control voltage
input at U
N3
"
Tab. 5-11: KMV - Cooling and power dissipation data
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
95/407
Technical data of the components
R911335703_Edition 04 Bosch Rexroth AG

Table of Contents