EasyManua.ls Logo

Bosch rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW - Service Functions;Troubleshooting; General Information

Bosch rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.4 Service functions/troubleshooting
11.4.1 General information
Lethal electric shock by live parts with more
than 50 V!
WARNING
Before working on live parts: De-energize installation and secure power
switch against unintentional or unauthorized re-energization.
Wait at least 30 minutes after switching off the supply voltages to allow
discharging.
Check whether voltage has fallen below 50 V before touching live parts!
The following section explains the tasks required to eliminate errors or
malfunction.
We distinguish the following actions:
Replacing fuses F4 and F5
Deactivation
Dismounting
Replacing the component
356/407
Commissioning, operation, diagnostics and maintenance
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Bosch Rexroth AG R911335703_Edition 04

Table of Contents