6.6.11 XG14, mains voltage synchronization
View Connection Function
L1 Connection to mains filter(XG14.L1)
L2 Connection to mains filter (XG14.L2)
L3 Connection to mains filter (XG14.L3)
Tab. 6-65: Pin assignment
Mechanical data
Screw terminal (connector) Unit max.
Connection cable
Stranded wire
mm
2
6
AWG 8
Stripped length mm 10
Tightening torque Nm 0.8
Tab. 6-66: Mechanical data
Cables
Description Value
Order type RKH0801
Maximum allowed length 1 m
Tab. 6-67: Cables
204/407
Connection points
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Bosch Rexroth AG R911335703_Edition 04