EasyManua.ls Logo

Bosch rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW - Maximum Number of Drives Per Drive Line

Bosch rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maximum number of drives per drive line
Power supply Drive Maximum number
HMV, HCS KSM02, KMS02, KMS03
≤ 30
1)
KMV03 KSM02, KMS02, KMS03
≤ 14
1)
1) The maximum number of drives per drive line depends on the
following factors: DC bus power, power requirement of control
voltage, Y‑capacitance and leakage capacitance of axes, cable
lengths. The module bus always limits the maximum number to
30.
Tab. 1-3: Maximum number of drives per drive line
6/407
System presentation
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Bosch Rexroth AG R911335703_Edition 04

Table of Contents