EasyManua.ls Logo

Bosch rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW - 14 Appendix; Digital Inputs; Digital Inputs Type a (Standard); Digital Inputs (Safety Technology L Options)

Bosch rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Appendix
14.1 Digital inputs
14.1.1 Digital inputs type A (standard)
Fig. 14-1: Symbol
Data Unit Min. Max.
Allowed input voltage V -3 30
High V 15 30
Low V -3 5
Current consumption mA 2 5
Control delay µs 1000 + position
controller clock
200 + position controller
clock
1)
1) Applies to optional I/O extension DA
Tab. 14-1: Digital inputs type A
14.1.2 Digital inputs (safety technology L options)
The digital inputs correspond to IEC 61131, type 2.
Fig. 14-2: Symbol
Data Unit Min. Max.
Allowed input voltage V -3 30
High V 11 30
Low V -3 5
Current consumption
1)
mA 7 15
1) For KCU02, the specified values must be multiplied with the
number of zone nodes of the drive line.
Tab. 14-2: Digital inputs (safety technology L options)
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
369/407