deTroubleshooting
Disturbance Cause and troubleshooting
E:18 or water inlet
indicator lights up.
1.Turn off the device.
2.Unplug the power plug.
3.Turn off the tap.
4.Unscrew the water connection.
5.Take the strainer out of the inlet hose
6.Clean the sieve.
7.Place the strainer in the inlet hose.
8th.Screw on the water connection.
9.Check the water connection for leaks.
10.Connect the power supply.
11.Turn on the device.
E:22 lights up.1 Sieves are dirty or clogged.
▶ Clean the sieves.
→
"Cleaning the sieves", page 47
E:24 lights up. Waste water hose is blocked or kinked.
1.Lay the wastewater hose without kinks.
2.Remove residue.
Siphon connection is still closed.
▶ Check the connection on the siphon and open it if
necessary.
Waste water pump cover is loose.
▶ Snap the wastewater pump cover into place
→
Page 61
correctly.
E:25 lights up. Waste water pump is blocked.
▶ Clean the wastewater pump.
→
"Cleaning the waste water pump", page 61
Waste water pump cover is loose
▶ Snap the wastewater pump cover into place
→
Page 61
correctly.
1Depending on the device reimbursement