17
Bosch Security Systems 03/10 BLCC100U
Solution16
Plus
User Guide
1.  Enter [MENU] + [3] + [0] + [5].
A list of dierent areas will display on the keypad.
2.  Use the [] and [] keys to select the area that you want 
to reset the smoke detectors, then press [OK] to select.  
Alternatively, you can enter the area number, then press 
[OK].
The keypad will display the following:
Smoke detector reset in
Progress. Please wait
3.  The keypad will automatically return to the menu when 
all smoke detectors in the area has been reset.
Inputs > Zone Properties >
Zone Name
MENU 3-1-0
This menu allows you to program up to 16 characters for the
name of each zone.
Enter programming mode (PIN + MENU) then,
1.  Enter [MENU] + [3] + [1] + [0].
A list of dierent zones will display on the keypad.
2.  Use the [] and [] keys to select the zone name that you 
want to change, then press [OK] to select.  Alternatively, 
you can enter the zone number, then press [OK].
The keypad will display the following:
Zone Name Z001
Zone 1 Name
Press
 OK to SAVE
3.  Use the [] and [] keys to scroll the cursor left and right 
across the zone name text.  Use the [] and [] keys to 
scroll through the dierent characters available.  To clear 
all text from the cursor position to the right, press the 
[OFF] key.
4.  Press [OK] to save and exit, or press [MENU] to exit 
without saving.
Inputs > Input Testing >
Walk Test All Zones
MENU 3-9-0
This menu allows you to test all zones within an area at the same
time. To successfully walk test each zone, you must open and
close each zone.
Enter programming mode (PIN + MENU) then,
1.  Press [MENU] + [3] + [9] + [0].
The keypad will display a list of areas that are available to 
walk test zones.
2.  Use the [] and [] keys to select the area that you want to 
do walk test, then press [OK] to select.  Alternatively, you 
can enter the area number, then press [OK].
The keypad will scroll all zones that you can test.
To test Z001
open then close
Zone 1 Name
Press OK or MENU
To test Z002
open then close
Zone 2 Name
Press OK or MENU
3.  Open and close each zone that needs to be tested.  A 
zone that has been successfully tested will no longer 
scroll on the keypad display.
When all zones have been tested, the keypad will display:
Selected zones have been
Tested OK
Press OK or MENU
4.  Press [OK] to save and exit, or press [MENU] to exit 
without saving. 
Inputs > Input Testing >
Walk Test A Single Zone
MENU 3-9-1
This menu allows you to select a single zone to be tested via walk
test.
Enter programming mode (PIN + MENU) then,
1.  Press [MENU] + [3] + [9] + [1].
The keypad will display a list of zones that are available to 
be tested via walk test.
2.  Use the [] and [] keys to select the zone that you want 
to walk test, then press [OK] to select.  Alternatively, you 
can enter the zone number, then press [OK].
The keypad will display the zone to be tested.
To test Z001
open then close
Zone 1 Name
Press OK or MENU
3.  Open and close the zone that needs to be tested. 
When the zone has been successfully faulted and 
restored, the keypad will display: