Solution16
Plus
18
Bosch Security Systems 03/10 BLCC100U
User Guide
Z001 Zone 1 Name
Test Successful
Press OK or MENU
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Outputs
The Solution 16
Plus
control panel has up to a maximum of 8
outputs. 4 outputs are available as standard with an additional
4 available when the optional output expander is tted. Your
installer will advise you on the exact makeup and conguration
of you system.
Outputs > Commands >
Output Status
MENU 4-0-0
This menu allows you to view the status of each output.
Enter programming mode (PIN + MENU) then,
1. Ensure that the system is turned o.
2. Press [MENU] + [4] + [0] + [0].
The keypad will display a list of outputs that the status
may be viewed.
3. Using the [] and [] keys, highlight the output that you
want to view the status information, then press [OK] to
select. Alternatively, you can enter the output number
and then press [OK].
The keypad will display the following when the output is
o and OK:
Output 1 Name O001
Is Off and Ready
Press OK or MENU
The keypad will display the following when the output is
o and missing:
Output 1 Name O001
Is Off and Ready
Connection Trouble
Press OK or MENU
The keypad will display the following when the output is
ON and OK:
Output 1 Name O001
Is ON and Ready
Press OK or MENU
The keypad will display the following when the output is
ON and missing:
Output 1 Name O001
Is ON and Ready
Connection Trouble
Press OK or MENU
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Outputs > Commands >
Turn Output On/O
MENU 4-0-1
This menu allows you to turn outputs that have been
programmed by your security company on or o. These outputs
can be programmed to control outside lighting, pool pumps,
watering systems etc.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [4] + [0] + [1].
If a valid PIN is required, the keypad will prompt you to
enter your PIN.
2. Use the [] and [] keys to select the output name
that you want to change, then press [OK] to select.
Alternatively, you can enter the output number, then
press [OK].
3. To toggle the output on or o, use the [ON] and [OFF]
keys.
The keypad will display the following when the output is
o:
Output 1 Name O001
Output is OFF,
To Turn ON,Press ON.
To Go Back Press OK
To turn the output on, press [ON].
The keypad will display the following when the output is
on:
Output 1 O001
Output is ON,
To Turn OFF,Press OFF.
To Go Back Press OK
To turn the output o, press [OFF].
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.