Solution 16
plus
14
Bosch Security Systems 09/06 BLCC100R
Quick Start Guide
To Hardware Default
1) Remove All Power To The System. AC and
Battery.
2) Press and Hold The Default Push Button
Down Then Apply Power To The System.
3) Release Button, The Panel Will Reset And
Revert To Normal Operation When Default Is
Complete.
To Software Default
1) Enter Program Mode.
[1234 +MENU]
2) Select Factory Default Option.
[MENU 7-0-4)
3) The Panel Will Reset And Revert To Normal
Operation When Default Is Complete.
You can disable factory defaulting using MENU 7-7-
4. If factory defaulting has been disabled you must
know the installer code to perform a factory default
otherwise the system will need to be returned to
your supplier for defaulting or you can purchase a
CM255 Default Unlock Key which will unlock the
panel in the field. Charges apply for defaulting if
retuned to the distributor.
Domes tic Template Defau lts
The following table list the changes that will occur when
you select domestic default.
Program Option Domestic Default Value
All Trouble Reports Disabled
All Bypass Reports
Disabled
All Restore Reports
Disabled
Destination 1 TX Format Domestic Reporting
Open / Close Reports Disabled (all areas)
System Events Route Log Only
Table 10: Domestic Keypad DIP Switch Address Settings
Dire ct L ink Pro grammi ng
The panel can be programmed via the Solution Link
Upload/Download software in either Direct Link or Remote
Link modes. For Direct Link you will need a CM900 Direct
Link module which connected the panels serial port to the
PC.
Once the cable is connected you will need to hold down
the default switch on the panel for 5 seconds to initiate the
programming session. See Figure 12: for the default switch
location. It is also possible to initiate the programming
session via [MENU 5-0-5] Start Direct Link.
Zon e Array
The feature allows you to view the condition of 16 zones
at a time on a single display. From the installer programing
mode press [Menu] 3-0-1 to access the zone array.
Use Keys [
] and [] to scroll up and down the zone bank
Press [OK] or [MENU] when finished.
N= NORMAL
S = SHORTED
A= ALARM
T= TAMPER
- = DISABLED
0000000001111111
1234567890123456
NSA-ANAT--------
PRESS , OK or MENU
Figure 20: Sample Zone Array Display
In the above example screen,
N = Zone 01 and 06 are Normal (Sealed)
S = Zone 02 is Shorted
A = Zone 03,05,07 are in Alarm (Unsealed)
T = Zone 08 is in Tamper Alarm (Unsealed)
- = Zone 04, 09-16 are Disabled (Unused)
Basic Repo r ting Refe ren ce
A complete reporting template is available on the Solution
Link CD or from your nearest Bosch security products
outlet. Your base station will need to create a specific
reporting template for this and other new model Solution
panels.
Point ID Table Module Description
Ur999 Installer
Ur998 Remote User
Ur001 - 256 Users
Ur000 Quick Arm
Zn301-428 User Keyfob 1 - 128
Zn891-898 Panels 1-8
Zn881-888 Keypads 1-8
Zn871-878 Ethernet 1-8
Zn861-868 GSM 1-8
Zn851-858 Output Expander 1-8
Zn841-848 Serial Expander 1-8
Zn831-838 Lan P/Supply 1-8
Zn821-828 RF Reciever 1-8
Zn811-818 Access 1-8
Zn801-808 X10 1-8
Zn781-788 Input Expander
Zn791-798 Lift 1-8
Zn001-128 Zones
Table 11: Basic Reporting Code Reference Listing