Program Loc ati ons
The following section lists all of the programming locations
available in the Solution 16
plus
. The default values for each
parameter are shown in grey.
In order to keep the size of this guide down to a minimum
we have shown only one example for some parameters
and then listed the default values for the other similar
parameters. For example the User Default Table below
shows the default values for Users 1 to 48. Similar tables
are used to show Zone Defaults etc.
Access Program ming
Use r Def ault Table
Parameter User 1 User 2 - 48
Add PIN 2580
Name User 1 User 2 - 48
Area Assignment
1 1
User Options
Has Master PIN Privileges
Y
Expire PIN Code
Is Arm Only Code
Can Bypass Zones
Y Y
Can Auto Bypass Zones
Y Y
Send Open/Close’ Reports
Y Y
Timer Group
Access Group
Table 13: User Default Programming Options
Access > Commands >
Erase User
MENU 1-0-0
Access > PIN Codes >
Change Own PIN
MENU 1-1-0
Change Other PIN
MENU 1-1-1
Add PIN
MENU 1-1-2
Delete PIN
MENU 1-1-3
View PIN
MENU 1-1-4
Access > Token >
Add Token
MENU 1-2-0
Delete Token
MENU 1-2-1
Token Status
MENU 1-2-2
Access > RF Keyfob >
Add Keyfob
MENU 1-3-0
Delete Keyfob
MENU 1-3-1
Test Keyfob
MENU 1-3-2
Access > User Properties >
User Name
MENU 1-4-0
U s e r 1 N a m e
Use the left and right arrow keys to scroll cursor left and right. Use Keys
[0] – [9] or the up and down arrows to scroll characters then press [OK]
To Save
Access > Global Properties >
Area Assignment MENU 1-4-1
1 Area 1 Y
2 Area 2 N
3 Area 3 N
4 Area 4 N
5 No Area N
6 No Area N
7 No Area N
8 No Area N
Access > User Properties >
User Option MENU 1-4-2
1 Has Master Code Privileges Y
2 Expire PIN Code N
3 Is Arm Only Code N
4 Can Bypass Zones Y
5 Can Auto Bypass Zones Y
6 Send Open / Close Reports Y
7 Reserved N
8 Reserved N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Access > User Properties >
Timer Group
MENU 1-4-4
0
Enter 1 - 8 + [OK] To Assign The User To A Timer Group – Can Only
Be Assigned To One Timer Group (0 = No Timer Group)
Access > User Properties >
Access Assignment MENU 1-4-5
1 Access Group 1 N
2 Access Group 2 N
3 Access Group 3 N
4 Access Group 4 N
5 Access Group 5 N
6 Access Group 6 N
7 Access Group 7 N
8 Access Group 8 N
Multiple Groups Can Be Assigned To Each User. Press 1 – 8 To Toggle
Groups On/Off, Then Press [OK] To Save.

Table of Contents

Other manuals for Bosch Solution 16plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 16plus and is the answer not in the manual?

Bosch Solution 16plus Specifications

General IconGeneral
BrandBosch
ModelSolution 16plus
CategorySecurity System
LanguageEnglish

Related product manuals