58 en | Installing the In-Ceiling Mount AUTODOME IP starlight 7000 HD
2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems
3. Cut and trim the wires allowing for sufficient slack to their respective terminals in the
box.
Notice!
If installing the camera to a drywall ceiling, allow enough wire to make the connections in the
Interface Box below the ceiling. Refer to the Wire the Interface Box section below.
4. Attach the remaining control data in/out wires to their respective terminals in the
Interface Box.
5. Connect the Ethernet cable to its mating connector J101 in the Interface Box.
6. Connect the 24 VAC power wires to the P101 connector in the Interface Box.
Connecting Alarm Inputs and Outputs
4 To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin
Alarms Out connector plugs with flying lead wires to the appropriate incoming alarm
wires. Alarm Out 4 is a relay.
Figure9.35: Alarm and relay connectors
1 4-pin Alarm
Connector (P102)
2 6-pin Alarm In
Connector (P103)
3 7-pin Relay Connector (P104)
Pin Description Pin Description Pin Description
1 Alarm Out 1 1 Alarm in 3 1 Alarm Out 4 Normally Open
2 Alarm Out 2 2 Alarm in 4 2 Alarm Out 4 COM
3 Alarm Out 3 3 Alarm in 5 3 Alarm Out 4 Normally Closed
4 Alarm Ground 4 Alarm in 6 4 Earth Ground
5 Alarm in 7 5 Analog Alarm 1
6 Alarm Ground 6 Analog Alarm 2
7 Ground
For in-ceiling mount only: Low Voltage TTL (3.3V) can also be used.
4 Connect the plugs to their mating connectors P103 and P102 in the Interface Box.
1. To connect supervised alarms and relays, attach the appropriate wires to their terminals
on the P104 connector on the Pipe Interface Board. Refer to the Connection, page 73
chapter for more details on wiring alarms.