AUTODOME IP starlight 7000 HD Installing the In-Ceiling Mount | en 59
Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679
2. Attach the lid to the Interface box:
Align the slots on the lid with the two posts at the rear of the Interface box.
Rotate the lid down.
Squeeze the ground clips, located at the front of the box, against the Interface box with
your fingers before closing the lid to ensure that the lid does not catch on the ground
clips.
Secure the lid to the Interface box by pushing the lid down until the clip on the lid
catches against the box.
9.6 Interface Box Connections
The following figure is a detailed illustration of the In-ceiling Interface box.
P105
P104
P102
P103
J101
J102
24VAC
24VAC
P101
SIG GND
TXD (-)
RXD (+)
C +
C -
NC
NO
COM
AGND
A2
A1
J103
A3
A4
A5
A6
A7
AGND
AGND
OUT3
OUT2
OUT1
Figure9.36: In-ceiling Interface Box
1 Fiber Optics 5 Coax Video
[Not applicable for AUTODOME
7000 Series cameras.]
2 Ethernet Video 6 Alarm In
3 Dome Power 7 Analog In
4 Data In/Out 8 Relay
The following table summarizes the pin connectors and their function:
No. Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7
P103 Alarms In Alarm 3 Alarm 4 Alarm 5 Alarm 6 Alarm 7 AGND
P102 Alarms Out Alarm 1 Alarm 2 Alarm 3 GND
P104 Analog Relay Relay N.O. Relay
COM
Relay N.C. Earth Alarm 1 Alarm 2 Ground
P101 24 VAC Line Earth Neutral