Control Panel
42
ASCII Dump Mode
ASCII Dump mode offers the option of checking incoming control sequences
at the interface when working with direct programming. The incoming
commands at the printer are printed out as text. In addition, a corresponding
error message is printed out immediately after an error occurs.
The printout is started after four lines have been received.
NOTE: Continuous media is most suitable for this function.
NOTE: You can adjust the width of the printout down to 2 inches
(50 mm) with the Width ASCII dump parameter.
1. Press the menu key.
2. Select Test > ASCII Dump Mode menu.
3. Press the
key to switch to Monitor mode.
4. Use the feed key to call up the last few lines of a label description.
You can cancel the printout with the cancel key.
Figure 29, ASCII Dump Mode