EasyManua.ls Logo

Brasilia EXECUTIVE - Page 51

Brasilia EXECUTIVE
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH / 24
TROUBLE-
SHOOTING
CAUSES
SOLUTIONS FOR
THE TECHNICIAN
SOLUTIONS FOR
THE USER
The group does
not deliver wa-
ter.
• The jet is obstructed
• The injector is obstructed
• (Only for versions with elec-
tronic dosing) the owmeter
connection is obstructed.
• The solenoid valve will not
open:
- The coil is not getting
power.
- The coil is broken.
- The core is blocked.
• Remove the jet plug,
check and clean or re-
place as nec-essary
• Dismantle and clean,
replace if necessary.
Note: check the regen-
eration of the softener
resins.
• Dismantle and clean
• Check solenoid
valve:
- Check and correct
the electric connec-
tions.
- Replace.
- Preferably replace
the complete sole-
noid valve.
Contact authorized
service agent
The boiler is un-
der pressure but
the group does
not heat up.
Air bleeding of the boiler did
not occur during the water
heating stage.
• The water heating circuit is
partially obstructed (except
lever machine).
• When cold check that
the air vacuum valve is
not blocked shut. Re-
place if necessary.
• Check the group’s
inlet and outlet pipes
and unions. Clean and
replace if necessary.
Note: check the regen-
eration of the softener
resins.
Contact authorized
service agent
The boiler will not
heat up.
• The heating element is
broken.
• The heating element is not
receiving power.
• The safety thermostat,
pressure switch and main
switch are faulty.
• Replace.
• Check and replace
the related compo-
nents.
• Check and replace if
necessary.
Contact authorized
service agent