Loading...
To
get off the
exueme
limit,
hold
down the
Power Enable pushbutton
while
turning
the
handwheel.
3.
Deduct
0.4 mm
from
the noted
<iisplay
figure
and enter the
result
as the
Machine
Parameter
for
the
relevant
axis.
i.e.
Parameter
31
for
the X
axis
Parameter
33
for
the
Y
o<is
Parameter
35
for
the
Z
axis
Deduct this
entered figure from
750.1
for
the X axis
from
360.1
for
the
Y
axis
from 125.1
for
the
Z axis znd
enter
the
result, as a negative
value,
for
the second Machine
Parameter of the relevant axis
i.e.
Parameter
32
for
the X axis
Parameter
34
f.or
the
Y
a;<is
Parameter
36
for the
Z
axis
4.
Using
joysticks,
check that axis
can be
run on
to its
software limits,
in rapid and off again
without operating
the
extreme
limits.
Check
that
the axis
stroke between
software
limits
is at least:
X=750mm
Y=360mm
Z=l25mm
Record
the new figures
on
the
Machine
Software
Parameter
Record
which can be
found
in
the door pocket
of
the electrical
cabinet.
6.6
CONTROLLER
BUFFER
BATTERY
REPLACEMENT
When
the
dialogue
display
reads
"EXCHANGE BUFFER
BATTERY"
the barteries
should
be
replaced
by new
ones
as soon
as possible.
MAINS
POWER
MUST BE
MAINTAINED
UNTIL
THIS
EXCHANGE
IS
COMPLETED.
The programme
memory
is
supplied
by
the mains power
supply
when the buffer batteries
are discharged.
Continued
operation
of
the
machine is
therefore possible.
However,
the memory
content
will be
erased
in
the event
of a mains
power
failure.
CAUTION:
Batteries
must
be replaced
witb
mains
power
supplied
to
tbe
macbine. Failure
to
obserue
tbis
principle
will
result
in a
partial
loss
of tbe
executiae
software.
The
battery
compartment
which
is
located
beneath
the
cover
plate
on the
control
panel,
contains
a
special
battery
carrier.
When inserting
new batteries,
care should
be
taken
that
the
polarity
conforms
to
the
polariry
signs
shown
on the
carrier.
The batteries
to be used
have
IEC
designation
"LRG" and
must be
of
the leak-proof
type.
we especially
recommend
the
use of Mallory
Alkaline
Batteries
Type
MN1500.