7.7 CHANGING AN IDENTIFICATION NUMBER
To change the ID number a cooler MUST BE powered and congured individually.
So, turn OFF the power to all the other coolers and heaters on the Network System�
Use the Installer Set-Up program as follows�
Turn the Brivis Networker OFF
Press  (clock)  Key  5  and  the  screen  will display  the  message  “Clock  setting mode”. After  the  message has 
nished ensure that the time is ashing.
Now simultaneously press and hold the 2nd & 4th keys for 3-5 seconds until the message displays “Installer 
parameter access”. After the message has nished the display will appear like this. If a Heater is also on the 
system you will need to press the Mode button�
Rotate the rotary dial to change the parameter value displayed at the top right of screen to the unit number
required for this Cooler (as shown below by unit number “ 2”).
Wait one minute before proceeding to allow for the programming change�
Press the Brivis Networker ON/OFF button to exit the program�
Turn the power supply at the Cooler OFF to save the new ID number
Repeat the sequence for each Cooler
Then follow the Brivis Networker Advanced Programming Instructions to allocate the Coolers to their respective
zones�
On/Off Button
Keys 2 and 4
Rotary Dial
Key 5 (Clock)
Parameter Value
Parameter Number
Cooler Number
E0 1 ID07: 1
On/Off Button
Keys 2 and 4
Rotary Dial
Key 5 (Clock)
Parameter Value
Parameter Number
Cooler Number
E0 1 ID07: 2
Brivis Advance, Brivis Promina & Brivis Contour Models Only:
EO1 IDO7: 1
Cooler Parameter Parameter
Number Number Value
Brivis AD Models Only:
EO1 IDO9: 1
Cooler Parameter Parameter
Number Number Value
Brivis Advance, Brivis Promina & Brivis Contour Models Only:
EO1 IDO7: 2
Cooler Parameter Parameter
Number Number Value
Brivis AD Models Only:
EO1 IDO9: 2
Cooler Parameter Parameter
Number Number Value
7. NETWORK CONNECTION

Table of Contents

Other manuals for Brivis Contour Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brivis Contour Series and is the answer not in the manual?

Brivis Contour Series Specifications

General IconGeneral
BrandBrivis
ModelContour Series
CategoryFreezer
LanguageEnglish

Related product manuals