9. TIMING & COOLER FUNCTIONS
9.1 START UP
Brivis Cooler with Dump Valve tted will have a 15 second delay on start up.
On start up, the Brivis C Series ServoSeal damper will also open before any other function�
If  the  Cooler  has  been OFF  for  longer than  60  minutes the  tank  will require  relling. Allow  approximately  3-5 
minutes depending on the water pressure�
9.2 PRE
-
WET
The Cooler has been pre-programmed to automatically saturate the lter pads when the pump is turned ON.
Pre-wet is the process of running the pump and wetting the pads without the fan operating ensuring full pad
saturation and optimum cooling potential when the fan starts�
Pump O󰀨 Time Pre-wet Time
Less Than 2 minutes No Pre-wet
Between 2 and 10 minutes Pre-wet 1 minute
Longer than 10 minutes Pre-wet 4 minutes
Longer than 60 minutes
Tank has to be lled, therefore total time 
including Pre-wet is 5 to 7 minutes
9.3 PROGRAMMABLE WALL CONTROL MODELS IN AUTO MODE
These models operate similar to Brivis Networker and Manual wall control models but in auto mode the Pre-wet
operates slightly di󰀨erently.
If the Cooler has been OFF for longer than 15 minutes it will begin with a 2 minute Pre-wet, then turn OFF the
pump and start the fan�
Depending on the room conditions and the wall control setting the Cooler may perform another Pre-Wet (as
described previously) when the pump is turned ON again, forcing the fan to turn OFF for that period�
9.4 TANK WATER QUALITY AND REPLENISHMENT DURING OPERATION
During the Cooler’s operation with the pump operating, the Cooler will be evaporating water from the tank and
automatically relling itself.
Brivis Advance and Brivis Promina Series models will periodically, after a specied number of tank rells, ush out 
the tank (discharging water from the drain outlet for approximately 1 minute) without stopping the Cooler
How frequently this ush occurs will vary according to local water conditions and the rate of evaporation.
NOTE
Brivis Contour Series will not ush as often, as they are tted with an AquaSave.
9.5 SHUT
-
DOWN TIMES
When the Cooler is turned OFF at the end of use, the controls are programmed to wait 60 minutes before
commencing Shut-down�
This Shut-down procedure starts with draining the tank (approximately 60 seconds)� Brivis Contour Series models
will also close the ServoSeal damper at the start of the Shut-down procedure� Then a wash cycle is performed to
clean the tank for approximately 30 seconds�

Table of Contents

Other manuals for Brivis Contour Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brivis Contour Series and is the answer not in the manual?

Brivis Contour Series Specifications

General IconGeneral
BrandBrivis
ModelContour Series
CategoryFreezer
LanguageEnglish

Related product manuals