The motor is not hot, causing the auto-reset thermal overload switch in the fan motor to open circuit�
The motor speed sensor has not been damaged or displaced (where tted).
That all electrical connections are secure, and if the motor will not start, call Brivis for service�
14.5 WHAT IF THE PUMP WILL NOT START?
Check:
The 10 Amp fuse in the meter box has not blown�
The Cooler’s 3-pin supply plug is correctly located in the power socket�
For power at the power socket (plug in another appliance and test)�
The isolating switches at the unit and the supply power socket are turned ON�
The unit is turned ON at the Brivis Networker/Wall Control�
The pump is not in a delay due to ServoSeal damper, or tank lling operation (Brivis Promina, Brivis Contour, 
Brivis Advance & Brivis AD Dump Models)�
The lter basket on the pump is not blocked (Brivis AD only)
The pump impellor is not blocked or obstructed�
All electrical connections are secure, and if the pump will not start, call Brivis for service�
12. COMMISSIONING CHECKLIST

Table of Contents

Other manuals for Brivis Contour Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brivis Contour Series and is the answer not in the manual?

Brivis Contour Series Specifications

General IconGeneral
BrandBrivis
ModelContour Series
CategoryFreezer
LanguageEnglish

Related product manuals