4-6 Confidential
Error Code
(Hex)
Symptom Probable Cause Solution
The number of performed
purge sequences has
reached the limit.
The ink absorber box may
be filled with drained ink.
Purge counter overflown
46
The number of flushing
operations has reached the
limit.
The flushing box may be
filled with drained ink.
Flushing counter
overflown
Replace both the ink
absorber box and flushing
box and reset their
counters. (When you
need to replace the ink
absorber box or flushing
box, replace both.)
47 Not used.
Correct the connection
of the head flat cables.
Replace the carriage
PCB ASSY.
Replace the
head/carriage unit.
48 Weak connection of the
head flat cables.
Head flat cables or
carriage-head flat cable
broken or not
connected
Replace the main PCB.
Head flat cables and
carriage-head flat cable
not connected correctly
Correct those flat cables.
Replace the carriage PCB
ASSY.
Head/carriage unit
defective
Replace the head/carriage
unit.
Main PCB defective Replace the main PCB.
49 The head drive voltage has
not risen to the specified
level.
Power supply PCB
defective
Replace the power supply
PCB.
4A-4E Not used.
Replace the carriage PCB
ASSY.
Piezoelectric ceramic
actuator defective
(Cracks or rare short)
Replace the head/carriage
unit.
4F The head drive voltage has
dropped from the high to
low level in an abnormally
short period.
The head drive voltage has
not risen to the specified
level within the specified
period in the self-
diagnosis.
Main PCB defective Replace the main PCB.