5. Maintenance
5-2-3. Replacing Flushing Plate Sponge and Flushing Plate Felt
(1)
Remove the Flushing Plate from the printer by lifting up the right side slightly and pull up to the right
direction.
(2) Remove the used Flushing Plate Sponge from the Flushing Plate and remove the waste ink inside. Put the
new Flushing Plate Sponge (top) into the Flushing Plate and mount the Flushing Plate as it is to the printer. If
the Flushing Plate Felt is very dirty, replace it.
<Note>
Keep clean the top edge of the Flushing Plate; if it is covered with dust and clogged ink, the Print Heads
may touch the surface and mis-firing may occur.
Dispose the used Waste Ink in accordance with your local regulations. Or make contact to your dealer.