4.2.6 Image distortion
4.2.7 All black
Step Cause Remedy
1
Laser unit attachment failure Reattach the laser unit, and firmly tighten 
the screws.
2
Dirt on high-voltage electrodes and 
electrodes of the machine
Clean the high-voltage electrodes and 
electrodes of the machine.
3
Laser unit FG plate attachment 
failure (not grounded correctly)
Retighten the screws to secure the laser unit 
FG plate.
4 Laser unit failure Replace the laser unit.
5 Main PCB failure Replace the main PCB ASSY.
<User Check>
- Clean the corona wire of the drum unit.
- Replace the drum unit with a new one.
Step Cause Remedy
1
Dirt on electrodes of the drum unit 
and those of the machine
Clean the electrodes of the drum unit and 
those of the machine. (Refer to Fig. 1-6 or 
Fig. 1-7.)
2
Connection failure of the laser unit 
flat cable
Reconnect the laser unit flat cable.
3
Laser unit FG plate attachment 
failure (not grounded correctly)
Check the contact of the laser unit FG plate, 
and retighten the screws.
4
High voltage power supply PCB 
failure
Replace the high voltage power supply PCB 
ASSY.
5 Laser unit failure Replace the laser unit.
6 Main PCB failure Replace the main PCB ASSY.