HL-2030/2040/2070N SERVICE MANUAL
Confidential
7-23
M-8 Fixing unit failure
Possible cause Step Check Result Remedy
Poor thermistor
harness contact
1 Is the contact of connector
CN7 on the main PCB good?
No Reconnect the connector.
Blown thermal
fuse
2 Remove the fixing unit and
measure the resistance of the
thermal fuse. Is it open
circuit?
Yes Replace the fixing unit.
Yes Replace the fixing unit. Thermistor
assembling
failure
3 Is the thermistor installed
properly?
No Reinstall the thermistor
properly.
Halogen heater
lamp failure
4 Remove the fixing unit and
measure the resistance of the
halogen heater lamp. Is it
open circuit?
Yes Replace the halogen heater
lamp.
Heater harness
connection
failure
5 Is the heater harness
connector connected to the
low-voltage power supply PCB
and fixing unit secure?
No Reconnect the connectors
securely.
NOTE:
This problem will be cleared if leaving the printer power ON for ten minutes.
If the heater is cooled down sufficiently, this problem may be cleared by turning on the
printer power switch while pressing the Go button. Be warned, however, that this
operation will melt the fixing unit if the heater is hot.
M-9 Main PCB failure
Possible cause Step Check Result Remedy
Main PCB 1 Is it possible to print the test
page with the method of ‘Test
Sample Page’ in Chapter 8?
No Replace the main PCB.
Software bug 2 Does this problem appear
when printing specific data or
printing under a specific
environment?
Yes Inform the Brother office of
the used specific data, printer
condition and system
environment.