Confidential
9-9
Error Code
(Hex)
Symptom Probable Cause Solution
No paper tray loaded. Load the paper tray.
Foreign materials in the paper
tray
Remove foreign materials.
Tail edge actuator caught on the
surrounding parts.
Reassemble the tail edge
actuator.
85 No paper tray loaded.
Tail edge sensor defective Replace the regist sensor
PCB.
86-87 Not used.
Paper is jammed. Remove the jammed paper.
Regist rear sensor actuator
caught on the surrounding parts.
Reassemble the regist rear
sensor actuator.
Foreign materials in the paper
path.
Remove foreign materials.
Regist rear sensor defective Replace the high-voltage PS
PCB ASSY.
Paper feed roller defective Replace the Paper feed roller.
F/R solenoid defective Replace the F/R solenoid.
Main motor defective Replace the main motor
ASSY.
88 Recording paper jam.
(The regist rear sensor
actuator is being push down
even after feeding paper.)
Main PCB defective Replace the main PCB.
Paper is jammed. Remove the jammed paper.
Regist rear sensor actuator
caught on the surrounding parts.
Reassemble the regist rear
sensor actuator.
Foreign materials in the paper
path.
Remove foreign materials.
Regist rear sensor defective Replace the high-voltage PS
PCB ASSY.
Main motor defective Replace the main motor.
89 Recording paper jam in the
manual slot (The regist rear
sensor actuator is not push
down after a certain time
elapses after paper feeding.)
Main PCB defective Replace the main PCB.
8A-A0 Not used.
Hook of the front open switch
on the front cover broken
Replace the front cover.
Front open switch broken Replace the front open switch.
A1 Front cover opened. (The
front open switch is not
pressed down.)
Main PCB defective Replace the main PCB.
Document jam Remove the jammed
document.
Actuator R caught on the
surrounding parts
Reassemble the actuator R.
Document rear sensor broken Replace the panel PCB
ASSY.
A2 Document length exceeding
the scan limitation.
During scanning, 90 cm or
longer of a document is
detected.
During document feeding or
ejecting, 400 cm or longer of
a document is detected.
Main PCB defective Replace the main PCB.