App. 7-1
Confidential
A7.1 Deleting User Setting Info from the Machine
The user setting information in the machine is recorded in the EEPROM on the main PCB. It
cannot be deleted all by a single operation. Use Function code 01 in the maintenance mode,
unplug the power cord from the electrical outlet, and disconnect the backup battery.
[ 1 ] Using Function code 01
Using Function code 01 (EEPROM parameter initialization) in the maintenance mode deletes
the following data that have been recorded in the main PCB:
Activity report
Station ID data
Outside line number
One-touch dialing
Speed dialing
Group dialing
Call transfer data
Operating Procedure
(1) On the machine, press the Menu and Black Start (Mono Start) keys in this order. Next
press the key four times to make the machine enter the maintenance mode. (Refer to
Chapter 9.)
TIP: Models equipped with a numerical keypad on the control panel can enter the
maintenance mode in the same way as conventional models; that is, by pressing the Menu,
*, 2, 8, 6 and 4 keys in this sequence.
The machine beeps for approx. one second and displays " " on the
LCD, indicating that it is placed in the initial stage of the maintenance mode, a mode in
which the machine is ready to accept entry from the keys.
(2) Press the 0 and 1 keys in this order in the initial stage of the maintenance mode.
The "SELECT 01?" appears on the LCD.
(3) Press the Black Start (Mono Start) key.
Parameter initialization starts and the "PARAMETER INIT" appears on the LCD.
(4) Upon completion of parameter initialization, the machine returns to the initial stage of the
maintenance mode.
[ 2 ] Unplugging the power cord from the electrical outlet and disconnecting the
backup battery
Unplugging the power cord from the electrical outlet and disconnecting the backup battery
deletes the Caller ID list, fax data received into memory, transmission verification report (for
image), broadcasting report and batch transmission data (in the memory).
Operating Procedure
(1) Unplug the power cord from the electrical outlet.
(2) Disconnect the battery harness from the main PCB. (See Chapter 6.)
(3) Leave the machine for approx. 24 hours.