85
PREDELIVERY
RUNNING CHECKS
5
Emergency Stop / Key Switch
Check emerg ency stop funct ion. With outbo ard
running at IDLE, pu ll sa fety lanya rd from emer-
gency stop switch . Outb oard must stop immed i-
ately.
Remote Control Operation
Make sure th at contro l can be easily move d into
all gear an d throttle settings. Do not shift remote
control when outboard is not running.
Start-In-Gear Prevention
Start outboard and shift to FORWARD.
Turn outboard OFF while control is in FORWARD.
Try to rest art the outboard. Outboar d sho uld not
start.
Shift back to NEUTRAL and restart outboard.
Shift to REVERSE. Turn outboard OFF while con-
trol is in REVERSE.
Try to rest art the outboard. Outboar d sho uld not
start.
Tachometer Pulse Setting
(SystemCheck)
Confirm accuracy of tachometer reading.
Adjust dial on back of t achometer to required
setting (the outboard should not be running).
I-Command Set up
Complete b asic se t up of I-Command g auges.
Configure engine and fuel tank, set fuel tank
capacity etc. Refer to I-Command User’s Guide.
Water Pump Overboard Indicator
A st eady stre am of water should flo w f rom th e
overboard indicator.
Operating Temperature
An o utboard run a t idle speed should a chieve a
temperature based on the engine’ s thermost atic
control. In general, the p owerhead temperatu re
should reach at least 104°F (40 °C) after five min-
utes of idling. Check that the powerhead reaches
idle temperature.
Idle Speed
Make sure th e outboard idles within the specifie d
idle RPM ran ge. If the outboard is run on a flush-
ing device, the idle speed a nd quality may not be
representative of actual in water use.
Break-In
Evinrude E-T EC o utboards req uire no brea k in.
When the outboard is delivered, re fer the cus-
tomer to the Oiling System information in th e
Operators Guide.
A WARNING
Make certain that the starter will not oper-
ate when the outboard is in gear. The start-
in-gear prevention feature is required by
the United States Coast Guard to help pre-
vent personal injuries.
Outboard Model Tachometer Setting
15–300 HP 6 Pulse or 12 Pole
1. Water pump overboard indicator 008469B
1

Table of Contents

Other manuals for BRP Evinrude E-TEC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BRP Evinrude E-TEC Series and is the answer not in the manual?

BRP Evinrude E-TEC Series Specifications

General IconGeneral
BrandBRP
ModelEvinrude E-TEC Series
CategoryOutboard Motor
LanguageEnglish

Related product manuals