98
Troubleshooting Failed Updates
1. If a gauge “times out” or does not successfully update, it will display a blank or white screen.
2. An error message will display if a device times out.
If either of these conditions occur, turn OFF power to the network. Disconnect the all the gauges from the net-
work at their tee connectors. Note which gauge(s) have a blank screen. Turn power back ON.
IMPORTANT: Read the remainder of this section BEFORE continuing.
Repeat the steps in “Update Software” on page 96.
3. After Step 4 of Update Software, an additional message will display.
Use the arrow keys to select YES.
Press the ENT button.
MENU
DOWN
UP
EXIT
PA
GES
ENTER
Software Update
Error
Some devices timed out and may not
have finished reprogramming.
OK
Updating LMF-400
Software Update
Warning
No units have been found to
reprogram. Do you want to try
anyway?
Yes No
Updating LMF-400
?