61
Fuel and Fluid Level Sensor
Calibration
Fluid level sensors use the tank sending unit to calculate remaining fuel, oil,
water etc. Calculation is based on sending unit accuracy, capacity entered
during setup, and liquid level in the tank. Use the FIVE POINT calibration to
achieve best accuracy.
•Two-Point calibrates EMPTY and FULL levels.
•Three-Point calibrates EMPTY, 50% and FULL levels.
•Five-Point calibrates EMPTY, 25%, 50%, 75% and FULL levels.
This example illustrates a 2-Point Calibration. Follow the on-screen prompts
if a Three or Five-Point Calibration is desired.
1. Press MENU. Use the UP or DOWN buttons and select SYSTEM SETUP.
Press ENTER.
2. Use the UP or DOWN buttons and select BUS DEVICES
Press ENTER.
WARNING
Running out of fuel could cause the operator of the boat to have
diminished or no control of the vessel, presenting a risk of personal
injury to the operator, passengers, and people who are nearby.
MENU
DOWN
UP
EXIT
PA
GES
ENTER
Customize
Pages
Screen
Audio Setup
System Setup
MENU
DOWN
UP
EXIT
PA
GES
ENTER
Eng Warnings
Change Units
Bus Devices
Sleep Mode
Sonar Alarms
Eng/Tank Cfg
1