5
Table 1 FACTORY--INSTALLED OPTIONS AND FIELD--INSTALLED ACCESSORIES
CATEGORY ITEM
FACTORY
INSTALLED
OPTION
FIELD
INSTALLED
ACCES SORY
Cabinet
Thru---the---base electrical or gas---line connections X X
Supply Duct Cover X
Coil Options
Cu/Cu indoor and/or outdoor coils
1
X
Pre---coated outdoor coils
1
X
Premium, E---coated outdoor coils
1
X
Humidity Control P erfect Humidity System (3 --- 12.5 ton) X
Condenser Protection Condenser coil hail guard (louvered design) X X
Controls
Thermostats, temperature sensors, and subbases X
RTU Open ---protocol controller X
Smoke detector (supply and/or return air) X
Time Guard II compressor delay control circuit X
Phase Monitor X
Economizers
& Outdoor Air
Dampers
EconoMi$ert IV (for electro---mechanical contro lled RTUs) X X
EconoMi$ert2 (for DDC controlled RTUs) X X
Motorized 2 position outdoor air damper X X
Manual outdoor air damper (25 % and 50%) X
Barometric relief
2
X X
Power exhaust X
Economizer Sensors
&
IAQ Devices
Single dry bulb temperature senso rs
3
X X
Differential dry bulb temperature sensors
3
X
Single enthalpy sensors
3
X X
Differential enthalpy sensors
3
X
Wall or duct mounted CO
2
sensor
3
X
Unit mounted CO
2
sensor
3
X
Gas Heat
Propane conversion kit X
Stainless steel heat exchanger X
High altitude conversion kit X
Flue Shield X
Flue Dis charge Deflector X
Indoor Motor & Drive Multiple motor and drive packages X
Low Ambient
Control
Winter start kit
4
X
Motormaster head press ure controller
4
X
Power
Options
Convenience outlet (powered) X
Convenience outlet (un---powered) X
Non ---fused disconnect
5
X
Disconnect Switch Bracket X
Roof Curbs
Roof curb 14---in (356mm) X
Roof curb 24---in (610mm) X
NOTES:
1. Novation coated coils only available with E ---coat.
2. Included with economizer.
3. Sensors used to optimize economizer performance.
4. See application data for assistance.
5. Available on units with MOCP’s of 80 amps or less.
580J