EasyManua.ls Logo

BSWA 308 - Page 94

BSWA 308
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BSWA 308/309 BSWA Technology Co., Ltd
92
Example: set auto power off as OFF
02 01 43 50 57 4F 34 03 3F 0D 0A
Return: ACK
02 01 06 03 06 0D 0A
PWO?: Query Auto Power Off Setting
Instruction
Parameters
Explanation
PWO
Query parameter: ?
ASCII
P
W
O
?
Hex
50H
57H
4FH
3FH
Byte
1
1
1
1
Return
Return auto power off settings
Example: query auto power off settings
02 01 43 50 57 4F 3F 03 34 0D 0A
Returns: the current auto power off setting is OFF
02 01 41 34 03 75 0D 0A
OPMp1: Set Boot Mode
Instruction
Parameters
Explanation
OPM
p1: Boot mode;
0=Normal;
1=Power & Boot;
2=Boot & Auto Measure;
Default: 0
ASCII
O
P
M
0
Hex
4FH
50H
4DH
30H
Byte
1
1
1
1
Return
ACK / NAK
Example: set bott mode as normal
02 01 43 4F 50 4D 30 03 21 0D 0A
Return: ACK
02 01 06 03 06 0D 0A