Loading...
Controls and instruments
© BT Industries AB 222714-040
23
Travel direction selector and speed con-
trol (1)
Select the travel direction by moving the lever, R, in the
required direction. The speed is controlled variably based on
the position of the lever. The brake is released at the same
instant the lever is activated. The speed when reversing
depends on the position of the lever. When the operator
releases the lever and it returns to the neutral position the
speed is automatically reduced.
Control for lifting and lowering the oper-
ator platform (2)
The control buttons activate a microswitch to start the pump
motor with lifting and to control the solenoid valve when lower
-
ing. The lowering speed of the platform is controlled by a flow
valve.
The diagram illustrates the controls, seen from the operator’s
position. Lift the platform by pressing A and lower by pressing B.
Note: The forks cannot be lowered when the truck has been
switched off.
Pallet to ground protection (Option)
Lifting/lowering of the forks can only be operated when the oper-
ator is present on the platform. Lowering stops when the fork
height is less than +/- 150 mm from the floor. From this position,
the forks can only be lowered further by releasing the lowering
button and then pressing it again.
Horn (3)
The horn sounds as long as the button is pressed.