Controls and instruments
© BT Industries AB 222714-040
24
Display (4)
A: Numerical field
B: Hour meter indicator
C: Parameter control
D: Battery indicator
E: Error indicator
The display provides the operator with information on battery
status, running time and any error messages. The display can
also be used for changing the operator parameters.
Numerical field (A)
The battery’s capacity is normally shown in this field in %, how-
ever, error codes and parameters can also be shown.
When driving walking at the side of the truck, “SLO” is shown in
the field.
When driving standing on the platform and this has been lifted
more than 500 mm, “HIgh” is shown in the field.
Hour meter indicator (B)
When this symbol is lit the running time can be read off from the
numerical field.
Parameter control (C)
When checking the set parameters the indicator window C will
light. The parameter list can then be read off from the numerical
field.
Battery indicator (D)
When this symbol is lit the battery capacity in % is shown in the
numerical field as set out below:
100% = Fully charged battery
0% = Discharged battery
The symbol starts to flash when the field indicates 10% battery
capacity, this is to attract your attention to the low battery capac
-
ity. When the field indicates a battery capacity of 0% the truck’s
lifting functions are disengaged to prevent overloading the bat
-
tery. The truck can still be driven so that it can be taken to the
charging station.
Error indicator (E)
When this symbol flashes an error code is displayed in the
numerical field. For the significance of the code see table
“Error
codes” on page 32.
A
B
C
DE