8.4 Maximum heating circuit temperature
The maximum heating circuit temperature is a target temperature that should not
be exceeded in the heating circuit.
The factory setting is:
This setting is only available for heating circuit 2.
Changing the maximum heating circuit temperature
With PERIM HTG system: 194°F (90°C)
With FLOOR HTG system: 122°F (50°C)
+
Press the "Display" key and "Install" key at the same time to call up the service
level. "AMERICAN" appears as the first main menu.
Turn the dial until "HEAT CIRC 2" is displayed.
Press "Display" to call up a submenu.
"PERIM HTG" or "FLOOR HTG" appears.
Turn the dial until "MAX TEMP" is shown.
+
Hold down the "Display" key and turn the dial until the required value appears
(in this case 140°F).
Release "Display" to store your input.
Press "ENTER" to return to the next higher level.
194
MAX TEMP
°F
140
MAX TEMP
°F
Logamatic 2107 controls - We reserve the right to make any changes due to technical modifications. 35
8
Heating circuit data
* This function does not replace the safety thermostat for switching of the pump
for radiant heating circuit.

Table of Contents

Other manuals for Buderus Logamatic 2107

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Buderus Logamatic 2107 and is the answer not in the manual?

Buderus Logamatic 2107 Specifications

General IconGeneral
CategoryControl Systems
TypeHeating Control Unit
Voltage230 V
Frequency50 Hz
Protection classIP20
Ambient temperature0°C
ApplicationHeating systems

Related product manuals