Cutting Unit CU and EGW
SnackFix
TM
2018-05 V1.8 31
5.9 Screen limits Cutting Unit CU:
min. Limit
This input field represents the lower limit of the respective axis. Enter the lowest
speed for the drive.
max. Limit
This input field represents the highest limit of the respective axis. Enter the
maximum speed for the drive.
Factor
This input field represents the factor of scaling of the respective axis.
Cutter Factor Continuous Mode
This input field represents the factor of scaling of the respective the cutter axis
in continuous mode.