8
4.4 Adjusting the spray pattern (HB 710 Spray only)
Thespraypatternisalteredbyadjustingthesprayair.
Settheoptimumspraypatternbyturningthespray-airchoke(14)intheprotectivesleeve
(13):
• Turningitclockwisedecreasesthespray-airpressure.
• Turningitanticlockwiseincreasesthespray-airpressure.
4.5 Automatic temperature reduction (ACE)
Unnecessarythermalloadingofthemeltshouldbeavoided.Thedevicethereforeswitch-
estostandbymodeatreducedtemperaturewhenthetriggerhasnotbeenactuatedfora
considerabletime(pausedoperation).
Intheconditionassuppliedthetemperatureisreducedby72°F/40°Cafter30minutes’
pausedoperation.TheprogrammingoftherelevantparametersisdescribedinSection
3.3.2.
BrieyactuatethetriggerortheUporDownbuttontoquitstandbymode.Thedeviceim-
mediatelyreheatstoworkingtemperature.
4.6 Switching off
1. PresstheStart/Stopbutton(6)forapprox.1suntilthedisplaygoesout.
2. Adjusttheoperatingpressuredownto“0”withthepressureregulator(3)ordisconnect
thecompressed-airsupply.
5 What if...
ThisSectionsummarisesthestatusanderrormessagesandprovideshelpineliminating
errors.
Ifmalfunctionsoccurpleasecheckrst
• hatthepowersupplyand
• compressed-airsupplyarefunctioningcorrectly,and
• whetherthereismechanicaldamagetothedeviceorsupplylines(powersupply,com-
pressedair).
Ifyoundanymechanicaldamage,thedevicemayinnocircumstancesbestartedup
again.Haveitcheckedandrepairedbyaqualiedserviceagent.
5.1 Status and error messages in the display
Indication Cause Action
Decimalpointonleftashes Warm-upphaseactive Thewarm-upphaseisendedwhenatem-
perature2°F/2°Cshortofthesetworking
temperaturehasbeenreached.
Decimalpointonrightislit Setpointloweringactive SeeparametersP1andP2(Section3.3.2)
ERR Permittedmaximumtem-
peratureof500°F/260°C
exceeded
Allowtocooldown
F1L Sensorfault,shortcircuit Havethedevicecheckedbyaqualied
serviceagent.
F1H Sensorfault,sensorbreakage Havethedevicecheckedbyaqualied
serviceagent.
-- Keylockactive SeeparameterP19(Section3.3.2)
EP Datalossinparametermemory Theregulatormustbereplacedbyaquali-
edserviceagent.