EasyManua.ls Logo

Buhnen HB 710 - Troubleshooting

Buhnen HB 710
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
5.2 Troubleshooting
Fault Possible cause Remedy See Section
Controllercannotbeswitched
onoroff
Microswitchattrigger
continuouslyactivatedor
defective
Eliminatedeadlockatmicro
switch(sheetmetaltongue)
orreplacemicroswitch
Nozzlegoesondripping Nozzlevalvepartiallyob-
structedordamaged
Drainthedevice.Actuate
thetriggerforapprox.5sto
clearthenozzle.
HB710:
Cleanorreplacenozzleend
HB 710 Spray:
Cleanorreplaceswirl
nozzle,pressurespringand
ball
6.2
Toolittleornomeltisdis-
charged
Operatingpressuretoolow Increaseoperatingpressure
(max.687psi/bar)
4.3
Compressed-airsupply
disconnected
Checkcompressed-airsup-
ply
Nozzlesystemclogged HB710:
Cleanorreplacecone
nozzleandifnecessary
nozzleend
HB 710 Spray:
Cleanorreplaceswirl
nozzle,pressurespringand
ball
6.2,6.3
Stocktemperaturetoolow Raisetemperature 3.3.1
Compressedairescapesfrom
closurecap(11)
Insufcientcoverpressure Increasecoverpressure 6.4
Gasketdirty Cleansealingfaces
Compressedairescapesfrom
serviceunit
Connectionsnotairtight Tightenorreplacegaskets
Sightglassofwatersepa-
rator(2)cracked
Replacesightglass
HB 710 Spray only
Spraypatternnotideal Spraypatternwronglyset Adjustsprayair 4.4
Nozzlesystemcloggedor
damaged
Cleanorreplaceswirl
nozzle,pressurespringand
ball
6.3.4
What, if…

Related product manuals