Type 2000
Technical data
15
6 TECHNICAL DATA
6.1 Conformity
The device conforms to the EC directives as per the EC Declaration of Conformity (if applicable).
6.2 Standards
The applied standards, which are used to demonstrate conformity with the directives, are listed in the EU
type examination certificate and/or the EU Declaration of Conformity (if applicable).
6.3 Type label
Made in G e r many
Flow 1
2000 A 50.0 NBR RG
G 2 Pmed 16 bar
Pilot 1.6 - 10 bar
00182076
W14UN
Device variant
Control function
Manufacture code (encrypted)
Flow direction
Type
2 R
Seat size
Seal material
Body material
Nominal pressure
Pilot pressure
CE marking
Order number
Connection type
Fig.4: Example of a type label
6.3.1 Designation of the actuator size
Actuator size [mm] Designation
ø40 C
ø50 D
ø63 E
ø80 R
ø100 G
ø125 H
Tab.2: Designation of the actuator size
6.4 Operating conditions
Degree of protection IP67 according to IEC 529 / DIN EN 60529
Flow media Water, alcohols, oils, fuels, hydraulic fluids, saline solutions,
lyes, organic solvents, vapour, air, neutral gases
Control media Neutral gases, air
Sound pressure level <70dB(A)