Maintenance, cleaning
DANGER!
Risk of injury from discharge of pressure and escaping
medium.
Dismantlingadevicewhichisunderpressureishazardousdue
toasuddendischargeofpressureorescapingmedium.
Beforedisassembly,shutothepressureandventalllines.
WARNING!
Risk of injury due to using wrong tool.
Performinginstallationwork,usingunsuitabletools,ishaz-
ardousduetopossibledamagetothedevice.
Toremovetheactuatorfromthevalvebody,useanopen-
endwrench,neverapipewrench.
Toreplacethepackinggland,usespecialinstallationwrench,
modiedsocketwrenchoropen-endwrench.
Observetighteningtorques.
Toreplacethepackinggland,rstremovetheactuatorfromthe
valvebodyandremovethecontrolcone.
Remove the actuator from the valve body
Clampvalvebodyinacollet(onlyforvalveswhichhavenot
yetbeeninstalled).
NOTE!
Damage to the valve seat seal or seat contour.
Whenturningtheactuator,thevalvemustbeintheopen
position.
For control function A
Without control unit:pressurisepilotairport1withcom-
pressedair(5bar).Valveopens.
With control unit:Openthevalveinaccordancewiththe
operatinginstructionsofthecontrolunit.
Actuator
Nipple
Valve body
Wrenchat
foropen-end
wrench
Pilot air port
Pilot air port
2
1
Fig.24: Valve
Placeasuitableopen-endwrenchonthewrenchatofthe
nipple.
Unscrewactuatorfromthevalvebody.