iNetVu New Gen Troubleshooting Guide
C-COM Satellite Systems Inc.
Step 5:
Disconnect the coax cable going into the “RXcable on the antenna.
Measure voltage on this cable. If the voltage does not match the output of the controller,
replace the cable. If the voltage does match, reconnect the cable and proceed to Step 6.
Step 6:
Disconnect the RX coax connected to the TRIA.
Measure voltage on this cable. If the voltage does not match the controllers output, it
concludes it’s an issue with the internal wire.
If the voltage does match, it concludes the TRIA may be the issue. Please replace the TRIA
and try again.
Please contact C-COM Technical Support for further assistance.