Calculated Industries DigiRoller - Calibrating the DigiRoller; Recalibration Process

Calculated Industries DigiRoller
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Calibrating the DigiRoller
You will need to recalibrate the DigiRoller if you:
change the wheel size
change the batteries (if you’re using a 2-ft wheel).
After changing the batteries, the unit resets the wheel circum-
ference size to 4 feet (the default size). You must reprogram
the unit to accept a different wheel circumference size so that
it will measure correctly.
1) Turn the unit on. Press the [Rcl] key and then press the
[RESET] and [+D] keys at the same time. You will see the
following*:
*NOTE: If you are in Metric Mode or have meters selected as
the current units of measurement, the display will
show approximately 1.22 meters.
2) Repeatedly press the [+D] key until the display shows the
desired wheel size. The unit will display the 2-foot, 3-foot
and 4-foot settings (note that we currently only provide
wheels with 2- & 4-foot circumferences).
3) Press the [RESET] key to clear the display and return the
unit to the measuring mode.
40 – DigiRoller/DigiRoller Plus