WATER FLOW SWITCH CONTACTS SHOWN WITH WATER FLOW AT MAXIMUM RATE
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED
WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY
NOTE
2.5A 4.5A32.0A
TEMPORISATION 1
12 HEURES
TEMPORISATION 2
6 MINS
TEMPORISATION
3
7 MINS
TEMPORISATION 4
10 SEC
CIRCUIT
VALEURS DISJONCTEUR
COMPRESSEURS
VENTILATEURS
DISJONCTEUR
COMMANDE
MONITEUR DE
PHASES
L3 L2 L1
RELAIS (R1)
RELAIS (R3)
PROTECTION
ELECTRONIQUE
COMPRESSEUR 1
CONTACT AUX
DISJONCTEUR COMP
2
PROTECTION
ELECTRONIQUE
COMPRESSEUR 2
CONTACT AUX
DISJONCTEUR COMP 1
PRESSOSTAT BP
(SE COUPE A 'H' EN
BASSE PRESSION)
PRESSOSTAT HP
(SE COUPE A 'L' EN
HAUTE PRESSION)
BORNES
D'INTERVERROUILLAGE
COMMUTATEUR
DEBIT D'EAU
ELECTROVANNE
(ARRET LIGNE LIQUIDE)
CURCUIT 1
ELECTROVANNE
(ARRET LIGNE LIQUIDE)
CURCUIT 2
VOYANT
CHAUFFAGE
VOYANT
REFROIDISSEMENT
VOYANT
DEFAUT
THERMOSTAT 2 CANAUX
CONTACT 7 ET 8 FERMES EN MODE CHAUD
CONTACT 4 ET 4 FERMES EN MODE FROID
VOYANT
DEFAUT
1
VOYANT
DEFAUT
2
VOYANT DEBIT D'EAU
VOYANT
TEMP OK
VOYANT ALIMENTATION
PRINCIPALE
VENTILATEUR
1
RECHAUFFEUR
COMP 2
VENTILATEUR
2
COMP
4
COMP
2
COMP
1
RECHAUFFEUR
COMP 1
RECHAUFFEUR
COMP 3
RECHAUFFEUR
COMP 4
SOUPAPE
D'INVERSION
CIRCUIT
FRIGORIFIQUE 1
CIRCUIT
FRIGORIFIQUE 2
SOUPAPE
D'INVERSION
COMMUTATEUR
VEILLE
DEMARRAGE AMORTI
DISJONCTEUR
THERMIQUE ET
VOYANT DE DEFAUT
(SI INSTALLE)
DEMARREUR OU
CONTACTEUR
DE DEBIT
CONTACT AUX
DISJONCTEUR
VENTILATEUR 2
CONTACT ALARME
DISJONCTEUR
VENTILATEUR 1
PROTECTION
THERMIQUE
VENTILATEUR 2
PROTECTION
THERMIQUE
VENTILATEUR 1
VOYANT LIMITE DE
REFROIDISSE-
MENT
(SE COUPE A 'H' EN BASSE
DE TEMPERATURE)
CIRCUIT FRIGORIFIQUE 1
CIRCUIT FRIGORIFIQUE 2
PRESSOSTATS LIMITE
DE REFROIDISSEMENT
CONTACT AUX
DISJONCTEUR COMP 4
PROTECTION
ELECTRONIQUE
COMPRESSEUR 4
PROTECTION
ELECTRONIQUE
COMPRESSEUR 3
CONTACT AUX
DISJONCTEUR COMP 3
PRESSOSTAT BP
(SE COUPE A 'H' EN
BASSE PRESSION)
CIRCUIT
FRIGORIFIQUE 1
THERMOSTAT DE
DEGIVRAGE
(SE COUPE A 'H' EN BASSE
DE TEMPERATURE)
VOYANT
DEGIVRAGE
DISJONCTEUR
COMP 3
DISJONCTEUR
COMP 2
DISJONCTEUR
COMP 1
CONTACTEUR
COMP 2
CONTACTEUR
COMP 4
CONTACTEUR
COMP 1
CONTACTEUR
COMP 3
DISJONCTEUR
COMP 4
COMP 4 AUX
DISJONCTEUR
CONTACTEUR
VENTILATEUR 2
CONTACTEUR
VENTILATEUR 1
DISJONCTEUR
VENTILATEUR 1
OUT 1
OUT 2
96
(N/F) 95
96
(N/F) 95
TK
TK
(N/F) TK
(N/F) TK
(COM) 1
MARCHE (I)
(N/O) 2
3 (N/F) VEILLE (O)
6 (COM)
1 (L)
(N) 2
(N/O) 4
(N/F) 5
2 (N/F)
4 (N/F)
6 (N/F)
12 (N/F)
4 (N/O)
1 (N/F)
6 (N/O)
3 (N/F)
SONDE
10
11
(COM) 7
(COM) 9
(COM) C
(N/O) H
L (N/F)
RELAIS (R5)
AB
(N/F) 1
(N/O) 4
7 (COM)
1 (N/F)
4 (N/O)
(COM) 7
3 (N/F)
6 (N/O)
(COM) 97 (COM)
(N/O) 4
(N/F) 1
1 (N/F)
(COM) 7
4 (N/O)
34
(N/F) 33
COMP 1 AUX
DISJONCTEUR
TRIP / OFF = BREAK CONTACT
15 (COM)
18 (N/O)
16 (N/F)
A1A2
(COM) 9
34
33 (N/F)
3 (N/F)
6 (N/O)
COMP 3 AUX
DISJONCTEUR
TRIP / OFF = BREAK CONTACT
15 (COM)
16 (N/F)
18 (N/O)
A1A2
TRIP / OFF = BREAK CONTACT
PRESSOSTAT HP
(SE COUPE A 'L' EN
HAUTE PRESSION)
(COM) C
(N/O) L
H (N/F)
(COM) C
(N/O) H
L (N/F)
RELAIS (R2)
AB
15 (COM)
18 (N/O)
16 (N/F)
A1A2
C (COM)
L (N/O)
C (COM)
H (N/O)
H (N/F)
L (N/F)
(N/F) 1
(N/O) 4 7 (COM)
AB
7 (COM)(N/O) 8
(N/F) 9
(COM) C
(N/O) H
L (N/F)
(COM) C
(N/O) H
L (N/F)
9 (COM)
6 (N/O)
3 (N/F)
AB
(N/F)
4 (N/O)
7 (COM)
1 (N/F)
(N/F)
(N/F)
(N/O)
(N/O)
34
(N/F) 33
COMP 2 AUX
DISJONCTEUR
TRIP / OFF = BREAK CONTACT
34
33 (N/F)
TRIP / OFF = BREAK CONTACT
TRIP / OFF = BREAK CONTACT
(N/F)
(N/F
TEMPORISATION 5
10 SEC
(SE COUPE A 'H' EN BASSE
DE TEMPERATURE)
CIRCUIT FRIGORIFIQUE 1 CIRCUIT FRIGORIFIQUE 2
A2A1
A2A1
COMP 2
CONTACTEUR
COMP 1
CONTACTEUR
A1 A2
COMP 3
CONTACTEUR
A2A1
COMP 4
CONTACTEUR
14 (N/O)
5
1
3
L1
L2
L3
11 (COM)
RELAIS (R4)
AB
CIRCUIT
FRIGORIFIQUE 2
THERMOSTAT
DE DEGIVRAGE
(SE COUPE A 'H' EN
BASSE DE
TEMPERATURE)
(COM) C
(N/O) H
L (N/F)
RELAIS (R7)
B A
RELAIS (R6)
B A
95
(N/F) 96
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
A2A1
DISJONCTEUR
VENTILATEUR 2
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
A2A1
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
95
96 (N/F)
TRIP / OFF = BREAK CONTACT
U
V
W
U
V
W
(N/F) 22
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)
63 (AUX)(N/O) 64
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)(N/F) 22
63 (AUX)(N/O) 64
7
6
9
8
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
COMP
3
U
V
W
U
V
W
(N/F) 22
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)
63 (AUX)(N/O) 64
(N/F) 22
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)
63 (AUX)(N/O) 64
95
96 (N/F)
TRIP / OFF = BREAK CONTACT
95
(N/F) 96
PP140(T)EHC TRIPHASEE (200V ~ 3 60Hz)
25
SD566250 ISSUE 35