80 ARGO Digital Broadcast IP Production Console
Specifications
ARGO CONSOLE PER-SECTION POWER MEASUREMENTS CONTINUED
VAC
(V)
Volt
AC (RMS)
(V)
Steady
State RMS
Current
(A)
* Worst
Case RMS
Current
(A)
Volt AC
(Plug-in
adapter)
(V)
Current
(Plug-in
adapter)
(A)
Power Factor
(Plug-in
adapter)
(%)
Power
(Plug-in
adapter)
(W)
Power Max
(Plug-in
adapter)
(W)
240 235.7 1.050 1.115 237 2.12 54 276 354
115 115 .7 1.221 1.439
100 100.9 1.392 1.638
3-Section Power Measurements
Mains Measurements below were taken at wall socket
with Plug-in Power measurement Adapter (NB:240V only)
* All faders moving at once
VAC
(V)
Volt
AC (RMS)
(V)
Steady
State RMS
Current
(A)
* Worst
Case RMS
Current
(A)
Volt AC
(Plug-in
adapter)
(V)
Current
(Plug-in
adapter)
(A)
Power Factor
(Plug-in
adapter)
(%)
Power
(Plug-in
adapter)
(W)
Power Max
(Plug-in
adapter)
(W)
240 235.4 0.840 0.910 237 1.77 47 192 247
115 115 . 0 0.999 1.061
100 100.4 1.079 1.220
VAC
(V)
Volt
AC (RMS)
(V)
Steady
State RMS
Current
(A)
* Worst
Case RMS
Current
(A)
Volt AC
(Plug-in
adapter)
(V)
Current
(Plug-in
adapter)
(A)
Power Factor
(Plug-in
adapter)
(W)
Power
(Plug-in
adapter)
(W)
Power Max
(Plug-in
adapter)
(W)
240 237.2 0.642 0.660 239 1.26 33 105 126
115 115 . 2 0.765 0.770
100 100.5 0 . 811 0.885
2-Section Power Measurements
Mains Measurements below were taken at wall socket
with Plug-in Power measurement Adapter (NB:240V only)
* All faders moving at once
1-Section Power Measurements
Mains Measurements below were taken at wall socket
with Plug-in Power measurement Adapter (NB:240V only)
* All faders moving at once