84 ARGO Digital Broadcast IP Production Console
Specifications
TYPE R -1U I/O BOXES
AD6501 Combo I/O 240V Operation 115V Operation 100V Operation
Supply Current
0.22 A 0.37 A 0.41 A
Power Factor
0.60 0.79 0.84
Power Dissipation (Heat)
31 W 34 W 34 W
Cooling
This 1U Rack is cooled by natural ventilation and does not require fan assistance, having
sufficient surface area to radiate heat adequately.
The side panels of the I/O unit should be unobstructed with at least 50mm (2’) clearance to
allow airflow. No clearance is required above or below the unit.
Operating Ambient Air
Temperature
0°C - 40°C
Weight
4.6 Kg (Includes US6525 AoIP Board weighing 0.04Kg)
Dimensions
430mm Width x 44mm Height x 363mm Depth (483mm Wide Front Panel)
AD6502 Analogue I/O 240V Operation 115V Operation 100V Operation
Supply Current
0.29 A 0.50 A 0.57 A
Power Factor
0.60 0.77 0.77
Power Dissipation (Heat)
41 W 44 W 44 W
Cooling
This 1U Rack is cooled by natural ventilation and does not require fan assistance, having
sufficient surface area to radiate heat adequately.
The side panels of the I/O unit should be unobstructed with at least 50mm (2’) clearance to
allow airflow. No clearance is required above or below the unit.
Operating Ambient Air
Temperature
0°C - 40°C
Weight
4.7 Kg (Includes US6525 AoIP Board weighing 0.04Kg)
Dimensions
430mm Width x 44mm Height x 363mm Depth (483mm Wide Front Panel)
JD6503 AES I/O 240V Operation 115V Operation 100V Operation
Supply Current
0.13 A 0.13 A 0.14 A
Power Factor
0.36 0.88 0.85
Power Dissipation (Heat)
11 W 13 W 12 W
Cooling
This 1U Rack is cooled by natural ventilation and does not require fan assistance, having
sufficient surface area to radiate heat adequately.
The side panels of the I/O unit should be unobstructed with at least 50mm (2’) clearance to
allow airflow. No clearance is required above or below the unit.
Operating Ambient Air
Temperature
0°C - 40°C
Weight
3.3 Kg (Includes US6525 AoIP Board weighing 0.04Kg)
Dimensions
430mm Width x 44mm Height x 239mm Depth (483mm Wide Front Panel)