Page 26 - Manual FB01002-EN - ver. 1 - 11/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
When the differential is active
(
), press button P
on the screen to read the value
of the temperature differential
setting C.
Use the
buttons to set the
dierential value at a value be-
tween 0 °C and 0.9 °C D.
By setting the dierential to 0 °C, during operation, a minimum switching on/o time of
1 minute is respected, regardless of the detected room temperature.
Press button P to exit programming.
Activating and configuring an integral proportional algorithm
This algorithm enables the programmable thermostat to reduce boiler power on cycles as
the ambient temperature approaches the set temperature, thus obtaining a considerable
reduction in consumption, maintaining the ideal level of comfort.
Three preset programs are available, suitable for dierent types of installations (P1, P2
and P3), or there is a completely manual program (P4).
When the dierential is not active
(
) B, press button P
to access the section in which it
is possible to select one of the
integral proportional programs
available E.