Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device Output Power supply (V) Power (W)
Accessories 10 - 11 24 AC 40
Additional light 10 - E 24 AC 15
Flashing beacon 10 - E 24 AC 15
Operator status warning light 10 - 5 24 AC 3
The output delivers 24 V DC when the batteries start operating, if they are installed.
Command and control devices
1
STOP button (NC contact)
This stops the operator and excludes automatic closing. Use a control device to resume movement.
When the contact is being used, it must be activated during programming.
See the [F1 – Total stop] function.
2
Control device (NO contact)
Open command
Partial Opening command
Partial Opening or Pedestrian command
When the [F6 – Hold-to-run] function is active, a control device must be set to OPEN.
See the [F8 – 2-3P command] function.
3
Control device (NO contact)
Step-by-step command
Sequential command
See the [F7 – 2-7 command] function
4
Card reader
5
Transponder selector switch
6
Keypad selector
7
Antenna with RG58 cable
If the chosen signalling device can be fitted with an antenna, use the terminal shown to connect it.
AB
S1 GND