Page 15 - Manual FA01768-EN - 07/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Signalling devices
1
Additional light
It increases the light in the manoeuvring area.
2
Flashing beacon
It flashes when the operator opens and closes.
3
Operator status warning light
It notifies the user of the operator status.
1
2
32
Safety devices
During programming, configure the type of action that must be performed by the device connected to the input.
Connect the safety devices to the CX and/or CY inputs.
If used, the contacts C1 CX CK must be configured during programming.
For systems with multiple pairs of photocells, please see the manual for the relevant accessory.
DELTA photocells
Standard connection
DELTA photocells
Connection with safety test
See function [F5] Safety devices test.
+
10
-
11 NO C NC
+
10
-
11
RX TX
+
10
-
11 NO C NC
+
10
-
11
RX TX