Page 13 - Manual FA01768-EN - 07/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
ELECTRICAL CONNECTIONS
Passing the electrical cables
Connect all wires and cables in compliance with the law.
The electrical cables must not touch any parts that may overheat during use (such as the motor and transformer).
Use membrane cable glands to connect the devices to the control panel. One of these must be intended exclusively for the power supply cable.
Power supply
Make sure the mains power supply is disconnected during all installation procedures.
Before working on the control panel, disconnect the mains power supply and remove the batteries, if any.
Connecting to the electrical network
F
Line fuse
L
Phase
N
Neutral
Earth
F
Power supply output for accessories
The output normally delivers 24 V DC.