10.2 - PROCESS FOR AUTOMATIC CALIBRATION OF THE GEARMOTORS
- The gate leaf of the second gearmotor perform a closing run and an opening run, ...
- With gate leaves fully ope, the PROG LED stays on for some seconds to show the proper automatic calibration.
If the LED fl ashes check the connections and repeat the calibration procedure.
- Press the “SET UP” button for about 3 seconds.
...Then, the gate leaf of the the fi rst gearmotor performs the same runs.
- Position the gate leaves so that they are half-way open by pressing on the “OPEN MOTOR” button.