p. 10 - Manual FA 01078- EN - 02/2018 © CAME S.p.A. - Translation of the original instructions
1 ON Automatic closing enabled (1
OFF-disabled); 2ON “Open-stop-close-stop” with button (2-7) and radio control
(with AF card fi tted) enabled;
2 OFF “Open-close”with button (2-7) and radio control (with AF card fi tted) enabled;
3 ON "Only open" with radio control (with AF card fi tted) enabled; (3 OFF-disabled);
4 ON Pre- ashwhen opening and closing enabled(4 OFF- disabled);
5 ON Obstruction detection enabled(5 OFF disabled);
6 OFF "Maintained action" (excludes the radio control) disabled (6 ON - enabled);
7 ON fi nal jolt enabled;at each opening and closing command, the gate leaves jolt inwards
for a second, to help release the electric lock connected to terminals 11-S. This
is active only if the leaves are closed and at the end of the operating time, or
at the fi rst maneuver after having powered up the system. (7 OFF - disabled);
8 OFF - 10 OFF Recloseduring opening functions (connect the safety device to
terminals 2-CX) enabled;
8 OFF - 10 ON Partial stop function (connect the safety device to terminals 2-CX) enabled (if the device connected to 2-CX
are unused, set DIP-switch 8 to ON);
9 OFFReopening during closing function enabled; with the safety device connected to terminals 2-C1 (if the device is unused,
set the DIP-switch to ON).
maximum of 120 seconds.
TRM2= To set the closing delay on Motor 2 from a minium of 0 seconds to
a maximum of 15 seconds, and simultaneously the partial opening from a minimum
of 0 seconds to a maximum of 30 seconds.
ACT = To set the automatic closing time from a minimum of 1 second to a
Adjusting the motor torque
To vary the motor torque, move the show faston to one of
the four positions:
1 min., 4 max..
Trimmer adjusting
OT = To set the operating time to a minimum of 10 seconds and a
maximum of 120 seconds.