Chapter 1
3
ventilated.
5) The floor of the machine must be level so that the feet of the machine will remain in contact and the machine will
remain level.
6) The machine must be at least 10 cm away from any wall, permitting unobstructed use.
F-1-2
7) The machine must be placed in a well ventilated area. It is important to make sure, however, that the machine is
not near the air vent (for suction) of the room.
1.1.2 Before Starting the Work (230V EUR)
0011-3206
iR2016J / iR2016 / iR2020
1-1 Points to Make Before Installation
Be sure to go through the following before starting the work:
1) If you are installing the machine after moving it from a cold to warm location, be sure to leave the machine un-
packed for at least 2 hours so that the machine is fully used to the site temperature, thus avoiding image faults
caused by condensation. (The term "condensation" refers to the formation of droplets of water on the surface of a
metal object brought in from a cold to warm place, i.e., as the result of the rapid cooling of the moisture (vapor)
around the object.)
2) The machine weighs a maximum of about 46 kg. Be sure to work in a group of 2 persons when lifting it.
1-2 Checking the Contents
Check to be sure that none of the following contents is missing:
100 mm min.
100 mm min.
1247 mm
1249 mm