Protocols or Network
services
Protocol ba‐
sis
Available protection Remarks
HTTP (inbound) HTTP There is no specific setting
to disable the HTTP proto-
col.
Inbound HTTP is enabled
as long as at least one of
the following services is
enabled:
- 'Océ Wave interface'
- 'Web Services for Devi-
ces'
- 'Allow interaction with
Océ Publisher Select'
- 'Océ Express Web Tools
via HTTP'
Inbound HTTP is totally
disabled when ALL afore‐
mentioned network serv‐
ices are disabled.
HTTPS (inbound) HTTPS Always Enabled - Cannot
be disabled.
' Allow automatic up-
date of embedded
Service documenta-
tion'
HTTP/
HTTPS
Enable/Disable Outbound connection
'Océ Online Services
connection enabled'
or
'Remote Service con-
nection'
HTTPS Enable/Disable Outbound connection used
by Remote Service
Note: To disable a network protocol or network service, go to the 'Configuration' - 'Connectivity'
section of the Océ Express WebTools and uncheck the protocol or service.
To disable the connection to Remote Service ('Océ Online Services connection enabled' or
'Remote Service connection' feature) , go to 'Preferences' - 'System defaults' - 'Service related
information'.
To allow/disallow 'automatic update of embedded Service documentation', go to 'Security' -
'Configuration' - 'Permissions for Service'.
Network protocols protection
Chapter 4 - Security on Océ PlotWave 345/365 and Océ PlotWave 450/550